The processing method when the sound of the three-phase asynchronous motor is abnormal or the vibration of the motor is abnormal.
Possible Causes:
(1) Wrong connection of the stator winding, local short circuit or grounding, resulting in unbalanced three-phase current and noise; (2) Foreign matter inside the bearing or serious lack of lubricating oil.
Approach:
(1) Check separately and prescribe the right medicine;
(2) After cleaning the bearings, replace with new lubricating oil for 1/2-1/3 of the bearing chamber.
motor vibration
Possible Causes:
(1) The installation foundation of the motor is uneven;
(2) The motor rotor is unbalanced;
(3) Unbalanced pulley or coupling;
(4) The shaft head is bent or the pulley is eccentric;
(5) The motor fan is unbalanced.
Approach:
(1) Flatten the base of the motor, and fix it after finding the level;
(2) Rotor calibration static balance or dynamic balance;
(3) Balance the pulley or coupling;
(4) Straighten the shaft, straighten the pulley and set the heavy car;
(5) Calibrate the fan.